
Sr Mechanical Cx Engineer, Data Center Engineering
Application completed on Apple
About This Role
Do you want to help build some of the largest and most consequential enterprise
and customer technology systems in the world? Join Apple’s Information Systems
and Technology (IS&T) organization. IS&T is the engine behind everything Apple
does for customers and for the people who build for them. It’s Apple’s central
nervous system. Supporting 2.5 billion active Apple devices, processing billions
of secure transactions, and keeping the technology that defines modern life
running flawlessly, IS&T makes the impossible feel effortless. Do you love
building solutions to handle global complexity and immense scale? Imagine what
you could do here. Infrastructure Services is part of IS&T and the foundation of
Apple's global network operations — managing data center equipment and systems
to deliver compute, storage, and networking services for teams across Apple,
including its internal developer community. From individual facilities to a
worldwide network, Infrastructure Services ensures the technology underneath
everything works without question. The Data Center Commissioning team is looking
for a Senior Technical Mechanical Engineer with depth in mechanical cooling
systems, hydronics, airflow dynamics, fire protection systems, and mechanical
building automation. The successful candidate will serve as the primary
mechanical technical authority across the full commissioning lifecycle (Levels
1–5) supporting all new Apple data centers, enterprise compute expansions, and
specialized critical spaces/labs.
DESCRIPTION
In this role, you will govern the end-to-end commissioning lifecycle by managing
third-party Commissioning Agents (CxA) rather than executing tests directly.
With a strong emphasis on technical oversight, script validation, and
cross-functional leadership, you will direct all project phases, including
design commissionability reviews, Factory Acceptance Testing (FAT),
Pre-Functional Testing (PFT), Functional Performance Testing (FPT), and
Integrated Systems Testing (IST).
MINIMUM QUALIFICATIONS
Bachelor's degree in Mechanical Engineering, Architectural Engineering, Systems
Engineering, or a related engineering discipline (or equivalent
practical/job-related experience). 5+ years of direct experience commissioning
and or managing the commissioning of mechanical and HVAC systems in a Hyperscale
data center environment. Understanding of large-scale mechanical cooling systems
(such as central chilled water plants, cooling towers, air-cooled/water-cooled
chillers, CRAH/CRAC units, and pumping infrastructure). Experience with the
commissioning, testing, and or validation of data center fire protection,
suppression, and early warning fire detection systems. Experience developing,
reviewing, approving, and or overseeing the execution of Level 4 (Functional
Performance Testing) and Level 5 (Integrated Systems Testing) test scripts and
procedures. Experience with mechanical Sequence of Operations (SOO) validation
under dynamic load conditions. Willingness and ability to travel approximately
40%, with availability for international travel as needed to support vendor
factory testing and global site commissioning activities.
PREFERRED QUALIFICATIONS
Professional Engineer (PE) license in Mechanical Engineering strongly preferred.
8+ years of mission-critical mechanical commissioning leadership experience
covering greenfield hyperscale data center campuses and specialized R&D/hardware
lab facilities. Deep practical expertise in high-density compute cooling,
including liquid-to-liquid / liquid-to-air Coolant Distribution Units (CDUs),
secondary fluid loops, manifold design validation, and direct-to-chip cooling
commissioning. Experience with commissioning management software platforms (such
as CxAlloy, Facility Grid, or similar tools) for script management, issue
tracking, and project reporting. Practical knowledge of Building Automation
Systems (BAS) and Direct Digital Control (DDC) platforms, including PID loop
tuning, sensor calibration validation, network architecture, and communication
protocols (BACnet, Modbus). Experience with data center load bank deployment,
variable-capacity heat-load testing strategies, acoustic testing, and thermal
imaging/infrared thermography. Demonstrated track record of resolving complex
field engineering challenges, conducting Failure Modes and Effects Analysis
(FMEA), and driving continuous improvement into corporate commissioning
standards and specifications. Experience utilizing data trending, BMS telemetry,
and Python scripting or data visualization tools to evaluate equipment
performance curves, plant efficiency (kW/ton, PUE), and transient response
during failover tests. Proficiency with AI tools to enhance daily work —
including AI-assisted authoring and redlining of commissioning scripts,
automated parsing of submittals and sequences of operations, and leveraging
predictive analytics and anomaly detection over operational telemetry.
